16ga White MIL-W-5086/2 Airframe Wire - Type 2

16ga White MIL-W-5086/2 Airframe Wire - Type 2
Product Code: 16ga White MIL-W-5086/2
Availability: In Stock
Price: $0.89

50 or more $0.79
75 or more $0.69
100 or more $0.59
Qty:     - OR -   Add to Wish List
Add to Compare
This product has a minimum quantity of 10

The original Wire for your Generator Set!

Price is per foot! 10 Feet Minimum!

 
Specifications  

Mil Spec No.

MIL-W-5086

Gauge

16

Stranding

19/29

Nom. Outer Diameter

0.105

Operating Voltage1

600 V

Temperature Rating

105 ºC

Conductor

Tinned Copper

Insulation

Polyvinylchloride (PVC) Fiberglass Braid

Jacket Material

Clear Nylon 22-10 gauge
Nylon Impregnated Braid 8-4/0 gauge

Color

White - stripes are available for color coding
In accordance with MIL-STD-104, Class 1; white preferred

Stranding (Number of Strands X AWG gage of Strands)

19 x 29

Min. Diameter of Stranded Conductor

0.052 in

Max. Diameter of Stranded Conductor

0.058 in
1 Voltage rating at sea level
 
Finished Wire  

Max. Resistance at 20ºC (68ºF) per 1000 ft.

4.81 ohms

Diameter

0.105 ± 0.005 in

Max. Weight

11.90 lb/1000 ft.
 
Mandrel Diameter (±3%)  

Mandrel Diameter (±3%) - Life Cycle (Oven and Bend Tests)

6.50 in

Mandrel Diameter (±3%) - Cold Bend Test

3.00 in

Mandrel Diameter (±3%) - Wrap Test

0.63 in
 
Test Load (±3%)  

Test Load (±3%) - Life Cycle (Oven and Bend Tests)1

1.00 lb

Test Load (±3%) - Cold Bend Test

3.00 lb
1 Also for bend tests after immersion.
 
Wire Ratings and Additional Requirements  

Max. Conductor Temperature Range

221 ºC
105 ºF

Blocking

105 ±2 ºC
221 ±3.6 ºF

Color Striping or Banding Durability

250 cycles (500 strokes) (min), 500 grams weight

Flammability (Method 1)

30 sec (max) after-flame
1.50 inches (max) flame travel, either direction on wire
No flaming of tissue paper

Humidity Resistance

40 megohms for 1000 ft, min insulation resistance after humidity exposure

Identification Durability

125 cycles (250 strokes) (min), 500 grams weight

Impulse Dielectric Test

Primary Insulation (When Test is used in Lieu of Spark Test): 6.0 kilovolts (Peak), 100% Test
Finished wire: 8.0 kilovolts (peak), 100% test

Min. Insulation Resistance for 1000 ft.

40 Megohms

Life Cycle (Oven Temperature)

120 ±2 ºC
248 ±3.6 ºF

Low Temperature (Cold Bend)

-55 ±2 ºC
-67 ±3.6 ºF

Shrinkage

0.125 inch Max. @ 150º ±2ºC (302º ±3.6ºF)

Smoke

110 ºC
230 ºF

Spark Test of Primary Insulation

3000 volts (rms), 60 Hz, 100% test

Surface Resistance

5 megohm-inches (min), initial and final readings

Thermal Shock (Oven Temperature)1

105 ±2 ºC
221 ±3.6 ºF

Wet Dielectric Test

2000 V RMS

Wrap Test (Oven Temperature)

95 ±2 ºC
203 ±3.6 ºF
1 The maximum shrinkage permitted for PVC insulation is .060 inch. Sizes 8 through 0000 gauge wire is permitted to have the braided polyamide outer jacket and glass braid insulation layers shrink .125 inch maximum.
 
Wrap Test Specimens  
In the selection of MIL-W-5086/2 wire specimens for the wrap test, each sample length from which a specimen is to be taken shall first be subjected to the dye inspection described under the wrap test procedure of MIL-W-5086, in order to detect glass fiber protrusions, if present, which permit dye penetration into the underlying braid. Specimens for the wrap test shall be cut only from those portions of each sample length which are free of such glass fiber protrusions.